WS601-UMB
Compact all-in-one weather sensor with measurement of temperature, relative humidity, precipitation intensity, precipitation type, precipitation quantity, air pressure, wind direction and wind speed.
Enquire about this productKey features
- Measuring wind direction and speed insusceptibly to bird nesting thanks to roofed construction
- All-in-one housing concept of a compact weather sensor combining 7 measurement parameters in one housing with only one cable connection
- Built-in data pre-processing, universal interfaces and selectable output protocols
- Compatible with many commercially available Met/HydroMet data loggers and PLS systems thanks to an open communication protocol
- Suitable for all climate zones; also for solar-powered automatic meteorological stations
- Ventilated temperature and humidity detection
From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications. Integrated design with ventilated radiation protection for measuring: Air temperature, relative humidity, precipitation intensity, precipitation type, precipitation quantity, air pressure, wind direction and wind speed. One external temperature sensor is connectable.
Technical specification
Dimensions | Ø approx. 164 mm, height approx. 445 mm |
Weight | Approx. 1.7 kg |
Interface | RS485, 2 - wire, half - duplex |
Power supply | 11…32 VDC |
Power supply | 5…11 VDC (electronics with limited precision of measurements) |
Power supply | 24 VDC +/- 10% (heater) |
Power consumption | 20 VA (heater) |
Operating temperature | -50...60 °C (with heater) |
Operating rel. humidity | 0...100 % RH |
Protection level housing | IP66 |
Standards/Regulations | Compliant to IEC 61724-1:2017 |
Mast mounting suitable for | Mast diameter 60 - 76 mm |
Cable length | 10 m |
Principle | NTC |
Measuring range | -50 ... 60 °C |
Unit | °C |
Accuracy | ±0.2 °C (-20...50 °C), otherwise ±0.5 °C (>-30 °C) |
Principle | Capacitive |
Measuring range | 0 ... 100 % RH |
Unit | % RH |
Accuracy | ±2 % RH |
Principle | MEMS capacitive |
Measuring range | 300 ... 1200 hPa |
Unit | hPa |
Accuracy | ±0.5 hPa (0...40 °C) |
Principle | Ultrasonic |
Measuring range | 0 ... 359.9 ° |
Unit | ° |
Accuracy | < 3 ° RMSE > 1.0 m/s |
Resolution | 0.1 |
Principle | Ultrasonic |
Measuring range | 0 ... 30 m/s |
Unit | m/s |
Accuracy | ±0.3 m/s or 3 % RMS |
Resolution | 0.1 m/s |
Accuracy | ±2 % |
Resolution | 0.2 mm |
Maximum intensity | 144 mm/h |
Accuracy | ±2 % |
Resolution | 0.5 mm |